Home 0483 26 11 50

Home › Heating problems › Pressure keeps dropping

Heating engineer · Brussels and Wallonia

The boiler keeps losing pressure

You topped up the pressure, and a few days later the needle is below 1 bar again. Topping up now and then is normal. Having to do it often isn't: water is escaping somewhere.

The most common causes

A small leak

A fitting, a radiator, a bleed valve or a pipe that drips, sometimes without a visible trace.

The expansion vessel

It absorbs the expansion of water as it heats. Once deflated, pressure rises when hot, then water escapes.

The safety valve

It opens at around 3 bar to protect the system. If it drips, pressure then drops when the boiler is cold.

Recent bleeding

After bleeding the radiators, you need to top up once: that's normal.

What you can check yourself

  1. Note the pressure with the boiler cold, then once it has been heating for a while.
  2. Look for water under the boiler, under the radiators and around the fittings.
  3. Check the small discharge pipe of the safety valve under the boiler: if it's running or wet, the valve has opened.
  4. Top up to 1.5–2 bar with the boiler cold (guide below) and keep an eye on it for a few days.

Don't

  • Topping up every week without finding the cause: fresh water brings air and limescale into the system.
  • Going above 2 bar when filling a cold boiler.
  • Touching the safety valve or the expansion vessel.

Call us if…

  • The pressure drops below 1 bar again within a few days.
  • It climbs close to 3 bar when the boiler is heating.
  • The safety valve drips or runs.
  • You can see a leak you can't stop.

What does a repair cost?

Call-out and diagnosis: €125 excl. VAT. The repair is extra, and you get its price before we start. We usually come within 24 hours (working days) and let you know 1 hour before we arrive.

This advice applies to most boilers. Every appliance has its quirks: if in doubt, your own manual applies, and we're happy to answer on the phone.

Frequently asked questions

My boiler is losing pressure but I can't see a leak: why?

Usually a deflated expansion vessel, or the safety valve opening when pressure rises with heat. A hidden leak, under a floor for example, is also possible. We check it on site.

The pressure climbs to 3 bar when the boiler heats up: is that serious?

Not dangerous straight away, that's what the safety valve is for. But it isn't normal: usually the expansion vessel no longer absorbs the expansion. Call us before the valve starts to leak.

What's the right pressure for a boiler?

Generally between 1 and 2 bar with the boiler cold, a little more when it's heating. Your boiler's manual gives the exact value.

Find out more

A breakdown, a question? Get in touch.

Call us or message us on WhatsApp. Or leave your number, with a photo of the boiler if you like: we'll call you back.

Photos (optional)

    A photo couldn't be read. Try a JPEG or PNG photo.

    Rather write? eylenbosch.clts@gmail.com

    Your details are only used to call you back and confirm your request. Privacy

    Call Call me back